超声冲击处理管接头疲劳设计曲线
王东坡, 王婷, 霍立兴, 张玉凤
天津大学材料科学与工程学院, 天津 300072
摘要:
采用T形管接头形式进行了20钢及奥氏体不锈钢1Cr18Ni9Ti焊态与超声冲击处理态的疲劳对比试验,对超声冲击处理管接头疲劳设计问题进行了研究。结果表明:(1)用热点应力表征,对于承载前进行超声冲击处理的管接头,其疲劳设计曲线的斜率m采用10较为合适,而对于承载后进行处理的管接头,m采用3.0较为合适;(2)当应力比R=0,20钢及奥氏体不锈钢1Cr18Ni9Ti承载前超声冲击处理管接头的相应疲劳设计S-N曲线(热点应力表征)为lgN=30.78-10 lgS;(3)当R=0.5,20钢承载前和承载超声冲击处理管接头的疲劳设计S-N曲线(热点应力表征)分别为lgN=28.0-10 lgS和lgN=13.37-3 lgS
关键词:  超声冲击处理  管接头  疲劳设计  S-N曲线
DOI:
分类号:
基金项目:国家自然科学基金资助项目(50405019)
Fatigue design curve of tubular joints treated by ultrasonic peening
WANG Dong-po, WANG Ting, HUO Li-xing, ZHANG Yu-feng
College of Material Science and Engineering, Tianjin University, Tianjin 300072, China
Abstract:
T tubular joints were used in the fatigue contrast tests of low carbon steel and austenite stainless steel 1Cr18Ni9Ti in two conditions:welded and treated by ultrasonic peening.The aim is for fatigue design problem research of tubular joints treated by ultrasonic peening.Test results indicate that:(1) If attributed by hot spot stress,10 is more appropriate for the rate of slope m of the corresponding fatigue design S-N curve as for the tubular joints treated by ultrasonic peening before loading,while 3 is more appropriate for it as for the tubular joints treated by ultrasonic peening after loading.(2) Under the stress ratio R=0,the corresponding fatigue design S-N curve(attributed by hot spot stress,m=10) of low carbon steel and austenite stainless steel 1Cr18Ni9Ti tubular joints treated by ultrasonic peening before loading is lgN=30.78-10lgS.(3) Under the stress ratio R=0.5,the corresponding fatigue design S-N curve(attributed by hot spot stress,m=10) of low carbon steel tubular joints treated by ultrasonic peening before and under loading are lgN=28.0-10lgS and lgN=13.37-3lgS respectively.
Key words:  ultrasonic peening treatment  tubular joint  fatigue design  S-N curve